How to Specify Plywood Bathroom Cabinet Finishes and Edge Sealing

Specify Plywood Bathroom Cabinet Finishes and Edge Sealing

To specify plywood bathroom cabinet finishes and edge sealing, list the cabinet body, back panel, doors, drawer fronts and drawer boxes as separate parts. For each part, record the core, face finish, back finish, edge band, adhesive, glue-line limit and cut-out treatment. Then approve one sample built the same way as production, and keep its revision number with the drawing and data sheets.

This article covers the specification record. For the question of whether plywood suits a bathroom at all, see our Is Plywood Good for Bathroom Vanities?

Key takeaways

  • “Plywood” in a quote names one board type. It does not describe the doors, drawer boxes or back panel.
  • Face layer, edge-band material, adhesive and glue line are four separate fields. Each needs its own entry.
  • ANSI/AWI 1232-2022 §3.4 sets no glue-line width limit, so the RFQ must state a number and a check.
  • On the manufacturer data read here, PVC and ABS band are not ranked: the two tie on several ratings and differ on others.
  • Cut-outs and site changes need a named product, a named owner and a recorded check.

What “Plywood” Means for the Cabinet Body, Doors and Drawers

In a plywood vanity cabinet specification, “plywood” names the core board of one single part, not the whole unit. Doors, drawer boxes and back panels often use different thicknesses or substrates, so record each part on its own line.

How plywood vanity supplier quotes split the carcass, doors and drawers

When a quote says “plywood”, it usually names the plywood cabinet carcass: the box made of the sides, top, bottom, back panel, shelves and toe kick. Doors, drawer fronts, drawer boxes and curved trim can use other substrates, so each part needs its own answer. A buyer cannot tell from the word whether “all plywood” or “plywood body, MDF doors” is meant.

Published vanity specifications show the split. One US frameless vanity lists a 3/4 in plywood case and 1/2 in 9-ply Baltic birch drawer boxes, which are two different plywood parts on one cabinet. A Chinese plywood vanity page lists an 18 mm plywood body with a 9 mm plywood back panel. The same word covers different thicknesses and grades in both.

The word also hides construction. Wood species, glue type and face-layer thickness each change how unfinished plywood takes up water. A report on one board does not cover the finished cabinet, because board data, hardware tests and cabinet stability tests each describe a different object.

Ask for a parts list before any finish question. Every finish, edge band and sealing choice below attaches to a named part. The choice between PVC, MDF and plywood is covered in PVC vs MDF vs Plywood Bathroom Vanities, and this article assumes plywood is already chosen.

plywood cabinet carcass door drawer construction
plywood cabinet carcass door drawer construction

One component schedule instead of one word

A component schedule lists each cabinet part with its core, finishes, edge treatment and open questions. The supplier fills in what it has confirmed and marks everything else “to verify”. Table 1 shows the fields.

Table 1. Component schedule fields for one plywood bathroom cabinet.

FieldWhat to recordVerify with
ComponentPart name: cabinet side, back panel, door panel, drawer boxConstruction drawing
CoreMaterial type, species, grade, plies, void limit and emission class (EPA TSCA Title VI, E1 or ENF)Board data sheet and certificate
ThicknessNominal thickness of the part, in mmBill of materials (BOM)
FaceMelamine, wood veneer with coating, or high-pressure laminateFinish data sheet
BackMelamine, sealed, or unfinishedSupplier statement and sample
Edge bandMaterial and thicknessBand data sheet
AdhesiveProduct name and gradeAdhesive data sheet
Glue lineMaximum width and how it is checkedApproved sample
Cut-outsBasin, pipe and hinge holesFactory or field responsibility
Drawing referenceRevision letter and dateApproved drawing set

Thickness is a field in this table, not a quality grade. KCMA A161.1-2022 requires the sides, tops, bottoms and backs of frameless cabinets to be “of thickness necessary to provide rigid construction to meet physical performance tests”, so the standard names no single plywood thickness. Write the figure for each part in the BOM, and give the back panel its own row.


How to Specify Plywood Bathroom Cabinet Finishes: Face, Back and Coating

To specify plywood cabinet finishes, record the face layer, the back-side treatment and the coating data sheet for each part. Naming only the visible front face leaves the back surface and raw edges open to uneven moisture uptake.

Melamine or veneer: what to write for each part

Melamine and wood veneer are both face layers, and neither one seals the board underneath. For each part, ask what the face is and what the back is. A protected face covers only the surface it sits on. Water enters through cut edges, holes and damaged finish, so those are the first places to inspect.

The back face needs its own line in the schedule. Uneven moisture response between a finished face and an unfinished back is a common cause of checking, warping and cupping in wood products, according to the USDA Forest Service finishing chapter. That is general wood-finishing guidance. It does not predict a given cabinet, and it does not mean both sides need the same coating.

Neither melamine nor veneer is better in general. The choice follows appearance and exposure, which Is Plywood Good for Bathroom Vanities? compares. In the specification, write the face, the back and the edge treatment as three entries.

What coating information to request for a veneered face

For a wood-veneer face, request the coating system, the data sheet version, the film thickness stated on that data sheet and any cure or conditioning requirement. A technical data sheet (TDS) is the manufacturer’s document listing a product’s intended use, application method and limits. “Waterproof lacquer” carries none of that. Record gloss level as an appearance field and confirm it on the approved sample.

Table 2. Face-layer questions for the supplier, by face type.

Face typeAsk the supplierThe answer must name
Melamine-faced plywoodWhich face-layer product, which back treatment, which edge bandFace product, back treatment, band material
Wood veneer with coatingVeneer species, primer and topcoat products, film thickness and cure conditions from the data sheetProduct names, TDS version
High-pressure laminate (HPL)Whether it is a decorative laminate bonded to the plywood or a self-supporting compact laminateLaminate type and thickness

The coating system and the edges are separate questions. For the US market, ANSI/AWI 0400-2022 defines factory priming as one primer coat on all surfaces and excludes concealed edges. It also asks for at least one coat of primer or sealer on raw-wood concealed surfaces of factory-finished components, again excluding concealed edges. Write “are concealed edges treated, and with what” as its own line.

Common mistake: Using a published finish-rating table in place of the supplier’s data sheet. Such ratings are judgments about generic products, and special formulations change the result.

plywood cabinet melamine veneer hpl finishes
plywood cabinet melamine veneer hpl finishes

Edge Banding Types, Adhesive and Glue Line: Specify Them as Separate Fields

Specify edge banding as three separate fields: the band material and thickness, the hot-melt adhesive grade and the maximum glue-line width. Naming only the band or the glue leaves the remaining fields to the factory’s default process.

Compare the edge-band types before you name one

Edge banding is a strip of material applied to a cut panel edge. A quote that says only “edge banding” does not say which material. Table 3 compares the types on the points that change a bathroom specification.

Table 3. Edge-band types for plywood bathroom cabinets. PVC and ABS figures come from one manufacturer’s data sheet and vary by grade. Confirm them on the data sheet of the band you buy.

TypeTypical use on plywood vanitiesVicat softening pointCleaner and chemical class (DIN 68861-1)What to confirm
PVCDoors, drawer fronts, carcass edgesAbout 67 °C“Very good”, class 1BBand thickness, back-side primer, grade data sheet
ABSDoors, drawer fronts, carcass edgesAbout 95 °C“Good”, class 1B; cleaners with solvents or alcohol advised againstCleaner list, grade data sheet
Wood veneer or solid-wood bandVeneer-faced doors and frontsNot tabulatedDepends on the finish applied over the edgeCoating on the band edge, finish system
Melamine paper bandHidden or low-exposure edgesNot tabulatedNot rated on standard band data sheetsWhether it is used on any edge, and which

On the same data sheet, PVC and ABS reach the same light-fastness rating (at least 6 on the blue scale) and the same shrinkage limit of 1.7% for a 3 mm band held 1 hour at 90 °C. ABS has the higher softening point. PVC is rated “very good” on chemical resistance against ABS’s “good”, and the sheet gives PVC a low stress-whitening tendency against an average one for ABS. So no single column ranks one plastic above the other. Choose by the part, the finish color and the cleaning method, and let the data sheet of the actual grade decide the rest.

ANSI/AWI 1232-2022 is the US standard for manufactured wood casework. For decorative laminate casework, §3.4.7.1 allows HPDL, PVC or ABS edges 0.5 to 3 mm thick, at the manufacturer’s or supplier’s option. PVC and ABS band thicker than 1 mm must be radiused or beveled on edges and corners. For transparent-finish casework, exposed edges use solid wood, veneer or veneer tape at least 0.5 mm thick. These rules apply only when the contract adopts AWI 1232.

Edge sealing depends on process as much as on the band

On plywood, the edge is the weak point, and the band is one layer of the seal. The edges of plywood contain end grain and absorb water quickly, and the right edge sealer depends on the surface finish. A correct band can still lift if the board was wet, the adhesive was cold or too thin, or the joint was loaded before it cured. REHAU’s band data sheet gives the processing conditions it expects. Turn them into questions the supplier answers in writing:

  • Board moisture and conditioning. KCMA A161.1-2022 requires solid wood and composite wood materials to be dried to a moisture content of 10% or less. REHAU gives 7 to 10% as the optimum board moisture and asks for room temperature above 18 °C during processing.
  • Edge preparation. REHAU lists pre-milling as a process step before gluing. Ask whether the supplier pre-mills, and ask for the core grade and void limit, so the band thickness is chosen with that core in mind.
  • Adhesive quantity. REHAU states the adhesive should be applied so that small beads press out from the edges of the freshly glued band and the voids between substrate particles are filled. The right amount depends on the board, its density, the band material, the feed rate and the adhesive type.
  • Temperature at the roller. REHAU notes the applicator roller temperature can differ from the set value by up to 30 °C.
  • Band age. Bands older than 12 months need a processing trial before series use.

A trial under the supplier’s real processing conditions is the check that ties these together.

What to ask when the quote says PUR edge banding

PUR edge banding is a band applied with a polyurethane reactive hot-melt adhesive. One-component moisture-curing PUR hot melts have been an established technology for decades. A PUR joint is not finished when it cools. One PUR data sheet states that the initial bond only holds the two parts together, and that final bond strength and resistance come after full curing, which depends on the substrate and the humidity. The same sheet gives 2 to 5 days to final strength, a softening point of about 83 °C and a heat resistance above 150 °C measured with a 0.6 mm oak-veneer edge. That heat figure does not transfer to a PVC or ABS band, and the cure time belongs to that one product.

REHAU says its ABS band can be processed with EVA, PA, APAO and PUR hot melts, and recommends adhesives with a high softening temperature for products exposed to high ambient temperatures, such as containerised transport. That is a point to raise for export orders.

Request these items from the supplier:

  • The adhesive product name, grade and data sheet version.
  • The substrates and edge materials listed on that data sheet.
  • The band’s back-side coating, if any, and whether the adhesive requires it.
  • The conditioning period before inspection, taken from the data sheet.
  • A trial under the supplier’s actual processing conditions.

Jowat states that customer trials under everyday conditions, suitability tests at normal processing conditions and fit-for-purpose testing are absolutely necessary. A name such as “PUR” or “zero bondline” does not settle bathroom suitability, because the combination of plywood, band and adhesive is what gets tested.

plywood cabinet pur edge banding on machine
plywood cabinet pur edge banding on machine

What glue-line width to write into the RFQ

The glue line is the thin strip of cured adhesive visible between the band and the panel. Neither ANSI/AWI 1232-2022 nor ANSI/KCMA A161.1-2022 sets a numeric limit on its width. AWI 1232 §3.4 asks only that glue or joint filler be “inconspicuous and match the adjacent surface for smoothness”. Its 0.4 mm figures limit flushness variation and gaps at mitered or butted joints, which is a different measurement. KCMA A161.1-2022 includes no glue-line width clause.

China’s voluntary group standard T/CNFPIA 3016-2021 (edge-banding quality requirements for customized household wood-based panel furniture) does give numbers. Its appearance table sets a maximum glue-line width of 0.5 mm and a maximum pinhole gap width of 0.2 mm. It defines “not obvious” as not visible to the naked eye at 0.4 m in natural light.

The standard’s 0.5 mm is a loose limit. An adhesive maker describes no more than 0.15 mm as the widely accepted market standard. It adds that even heavily filled ordinary EVA can reach 0.1 mm under reasonable process conditions, and that unfilled transparent adhesive can reach about 0.05 mm. The same source says the edge-banding process has a greater influence on glue-line thickness than the adhesive does, and that a continuous glue line with no pinholes is the precondition for passing a water-soak test.

The glue line is therefore a number the buyer has to choose. Table 4 shows a grading a buyer can write into an RFQ. Only the 0.5 mm and 0.2 mm limits are from a standard. The rest are suggested RFQ limits, labeled by their basis.

Table 4. Suggested glue-line grades for plywood bathroom cabinet edges, with the basis of each number.

Glue-line widthSuggested useBasis
Above 0.5 mmFails the appearance limitT/CNFPIA 3016-2021
Above 0.20 mmSuggested reject for exposed bathroom edgesRFQ convention, not a standard
0.10 to 0.15 mmSuggested limit for carcass edgesMarket limit of 0.15 mm
0.05 to 0.10 mmSuggested target for exposed doors and frontsReported reachable with unfilled adhesive

A thinner line is not automatically a stronger one. Pinholes and starved spots matter more than the nominal width, which is why the water-soak and peel checks in the reports section sit beside the width limit. Laser and hot-air bonding remove the visible adhesive line almost entirely. Henkel reports that the latest PUR hot melts come close to laser edge banding on fine joins, that PUR resists water better, and that the near-invisible laser join can develop into a more obvious glue line over time. That is a manufacturer’s view. Public tests rarely cover laser bonding on plywood end grain. Ask any supplier offering a zero-line edge for its own soak and peel results on plywood.

Here is wording that can go straight into an RFQ:

Glue line on exposed doors and drawer fronts: maximum 0.10 mm, continuous, no pinholes, color-matched unfilled adhesive. Glue line on carcass edges: maximum 0.15 mm. Checked on the approved sample under natural light at 0.4 m, and with a feeler gauge at corners. Adhesive grade, application weight and conditioning period stated on the supplier’s data sheet.

Those limits are the buyer’s choice. Give the supplier the number, the viewing condition and the check method, and record what the sample shows.

Common mistake: Writing “invisible glue line” in the RFQ. It has no width, no viewing distance and no check, so the production run can use a different product from the sample.


Plywood Bathroom Cabinet Edge Sealing and Cut-Outs: Who Seals What, and How You Check It

Specify edge sealing and cut-outs by assigning a named sealer, an owner and a check to every hidden edge and plumbing hole. Cabinet standards cover visible edges, so concealed edges and cut-outs stay unprotected unless listed.

Which edges the standards cover, and which they leave out

Two US standards word the edge rules differently, and each applies only when the contract adopts it. Table 5 compares their edge clauses.

Table 5. Edge clauses in two US standards.

EdgeANSI/AWI 1232-2022 (casework)ANSI/KCMA A161.1-2022 §8.1.1 (kitchen and vanity cabinets)
Door edgesEdgebanded at all four edges, except back-beveled or solid-wood doors. Opaque-finish doors: all edges filled or edgebandedExposed exterior edges free of saw marks and imperfections, filled and sanded, edge-banded or otherwise finished
Drawer-front edgesEdgebanded at all four edges, same exceptionsSame exposed-edge wording
Side edges and back-panel edgesNot specified as a separate rule in §3.4Excluded from the clause

KCMA §8.1.1 applies its finish requirement to all exterior exposed surfaces and edges except the edges of sides and the edges of back panels. Those edges are outside the clause, so the specification must state them. Both standards describe appearance and fabrication. Neither is a waterproofing clause. In the schedule, add one line per hidden edge: bottom edge, back edge and hinge-side edge.

Fluted side storage cabinet for bathroom vanity
Fluted side storage cabinet for bathroom vanity

Cut-outs, drilled holes and field-cut edges

A cut-out is any opening machined into a panel, such as a basin or pipe opening. ANSI/AWI 1232-2022 §3.4.6.2 sets a minimum 6.4 mm (0.25 in) radius at inside corners. Where a cut-out and its access panel leave a reveal wider than 3.2 mm (0.125 in), the edges must be painted or edgebanded. These are appearance clauses. They do not govern how a plumbing hole is sealed.

A cut made after the sample was approved exposes core that no factory process has treated. Basin cut-outs, pipe openings and hinge holes each need an owner and a check. Table 6 shows a sample record that the buyer and supplier fill in before sample approval.

Table 6. Sample coverage and responsibility record for cut-outs and edges.

LocationCore exposed after processingProduct and data sheetFactory or fieldCheck and photoChange order
Top-rail basin cut-outYes, plywood end grain2-coat PU edge sealer (attach TDS)FactoryPhoto before packingNone
Back-panel pipe openingYes, cut hole wallNeutral silicone or PU sealer (attach TDS)FieldSite photo before hookupCO-01 if moved
Concealed hinge cup holeYes, bored pocketFactory sealer or press-fit cup flangeFactoryApproved sample checkNone

Check factory-cut and site-cut plywood edges against the selected finish and its resealing instructions. A sealant must come with its own suitability statement for plywood and for the existing finish, so ask the supplier to name the product and attach its data sheet.

Log every site change with its product

Field work changes the cabinet after the sample was approved. Record each change with six entries: the product and its purpose, the substrates the manufacturer allows for it, the data sheet version, the application and recoat conditions, the change order number and the approver’s name.

Common mistake: Treating a groove or a bead of silicone around a hole as proof that the core is treated. Only the recorded product, the surface it was applied to and the check photo show what was done.


Approve One Sample Built the Same Way Before Bulk Production

An approved sample is one finished unit, built with production materials and methods, that both parties sign off against a recorded drawing and data sheet set. It shows the face, back, edge, a corner and one representative cut-out, and it carries the drawing, BOM and data sheet versions that production will use. Dlinxcy builds pre-production samples in about 7 days and keeps a matching sample on the line for batch checks. See our sample approval and quality control pages for the full workflow.

  1. Freeze the specification. Lock the drawing revision, the schedule from Table 1 and the data sheet versions for board, band, adhesive and coating.
  2. Build the sample on the production line. Use the same core, face, band, adhesive and edge process.
  3. Wait for the adhesive to cure. Inspect after the conditioning period on the adhesive’s data sheet, not on the day of production.
  4. Inspect each line of the schedule. Check face, back, edges, corners and cut-outs, and photograph each with a scale in frame. Measure the glue line against the RFQ limit.
  5. Record the result. Write pass, conditional pass or fail, list every deviation, and add the sample number, approver and date.
  6. Seal the sample and the record. Any later change to board, band, adhesive, finish or cut-out treatment needs a new approval.
  7. Compare the first production lot with the sealed sample and the record.

Table 7. Sample approval record fields.

FieldWhat to record
Sample IDTracking number on the sample and its photos
Drawing and BOM versionRevision letter and date
Face, back, edge and cut-out photosPhotos with a scale in frame
Glue-line measurementWidth at the checked points, viewing condition
Adhesive grade and cure periodData sheet version, date made, date inspected
Appearance requirementsColor, grain and gloss agreed by both parties
Related reportsReport number and a photo of the specimen it covers
Care and repair limitsAllowed cleaners and touch-up scope
DeviationsOpen issues and the conditions for closing them
Approver and dateName, signature and date
Re-review after a field changeYes or no, and the new approval reference

A sample that looks flush and clean does not show that the adhesive has cured or that the next batch will match. Ask when it was made and when it was inspected. See Dlinxcy Wholesale & Custom Plywood Bathroom Vanity Cost.


Which Reports and Care Documents Support the Finish Specification

A test report supports a finish specification only when its specimen, tested surfaces and procedure match the part being specified.

KCMA A161.1-2022 is a performance and construction standard that states no intent to specify cabinet design or materials. Its chemical test applies to the door, face frame, drawer front and side, and to the substances the test lists. Its door-edge detergent test sets 24 hours on the sponge for doors without seams at the contact point and 4 hours for doors with seams, such as edgebanded doors. The two durations are not a ranking of finishes. The tests run on surfaces aged at least 10 days. None of this is a whole-cabinet immersion test.

T/CNFPIA 3016-2021 tests the edgebanded panel itself. Its physical tests cover cold and heat cycling, high temperature, a soak test and 90° peel strength. The soak lasts 2 hours for EVA-bonded edges and 8 hours for PUR or other adhesives, with edge swelling of at most 0.3 mm. For plywood edgebanding, peel strength must be 3.0 N/mm or more. That value depends on the board type and on whether the face is visible, not on the adhesive. It is a Chinese group standard and does not replace the KCMA tests for a US order.

In the EU, BS EN 14749:2016+A1:2022 specifies safety requirements and test methods for kitchen and bathroom storage units. It excludes requirements for resistance to ageing and degradation, so a pass says nothing about how long a finish lasts. BSI also lists EN 12720 (surface resistance to cold liquids) and EN 12721 (surface resistance to wet heat).

Cleaners need a separate check. Compare the buyer’s cleaning products with the finish manufacturer’s guidance by product name, dilution, contact time and scrubbing tool. A KCMA chemical test does not cover every cleaning or disinfecting agent. For ABS band, REHAU advises against cleaners that contain solvents or alcohol.

Common mistake: Filing a report for a different board or finish as proof for the quoted cabinet. Ask for the specimen description and a photo, and match them to the part in the schedule.


Frequently Asked Questions

Q1: What thickness of plywood is best for bathroom cabinets?

A: There is no single “best” plywood thickness for every bathroom cabinet; specify it by part. A common moisture-resistant vanity spec is 3/4 in (18–19 mm) plywood for carcass sides, bottom, top and shelves; 1/2 in (12 mm) for drawer boxes; and 1/4–1/2 in (6–12 mm) for the back panel depending on rigidity and mounting. Use moisture-resistant/exterior-glue plywood and seal cut edges. Frameless cabinets, long spans or heavy loads may need 3/4 in plus bracing. KCMA A161.1-2022 does not prescribe one thickness; check hardware ratings and local requirements, and list the chosen thickness by part in the BOM.

Q2: Is there one glue that works on both PVC and ABS edge banding?

Yes, in many cases one adhesive can bond both PVC and ABS. Common EVA hot melts (e.g. Rakoll TE 5732, Kiiltomelt W 401) and PUR hot melts (e.g. TAKA 3308.20, Henkel Technomelt PUR 270/9) are routinely specified for both PVC and ABS edgebanding. But do not stop at the chemical family name: check the adhesive’s own TDS for both the edge material and the substrate (MDF, particleboard, etc.), confirm any primer requirement, and run a trial at your line’s actual feed speed and temperature. REHAU’s ABS statement confirms ABS processability; it does not mean PVC is excluded.

Q3: Which edge banding is better for a plywood bathroom cabinet, PVC or ABS?

For a plywood bathroom cabinet, ABS edge banding on a PUR glue line is the more defensible default, not because ABS is “better” in the abstract, but because the bathroom failure mode is moisture ingress at the glue line, and ABS’s lower water absorption and lower thermal expansion put less stress on that line under humidity and temperature cycling. PVC remains viable where budget dominates and the band is thick (≥1.5–2 mm) and bonded with PUR, but standard PVC + EVA is a weak combination for a wet room. What matters most is a fully banded edge, adequate thickness, and a moisture-resistant adhesive — confirm the glue line on a sample of your actual plywood edge.

Q4: Will lacquer make plywood bathroom cabinet finishes waterproof?

No — lacquer alone will not make a plywood bathroom cabinet waterproof. A coating only protects the surface it covers; plywood edges, cutouts and the back/bottom are the weak points, and moisture enters there. A full coating system can make the cabinet water-resistant, not waterproof. For a bathroom, start with moisture-resistant plywood, seal all exposed edges with a compatible edge sealer, and specify the coating system by product name: primer, topcoat chemistry (e.g. 2K PU, waterborne acrylic or conversion varnish rather than generic nitro lacquer), number of coats, dry-film thickness and cure schedule. Confirm adhesion and water resistance on a sample, and do not accept “waterproof finish” as a specification.

Q5: Can a plywood vanity be made bespoke?

Yes, can custom or bespoke plywood vanity. when drawings, the component schedule and a sample record define the build. Custom size, face finish, edge band and cut-out positions are all fields in the schedule, and the supplier states which of them it can meet. Approve a sample built the same way as production before bulk production starts.


Conclusion

Decide plywood bathroom cabinet finishes and edge sealing part by part. Each part gets its own core, face, back, edge band, adhesive, glue-line limit and cut-out entry, and each site change gets a logged product. An approved sample, built like production, inspected after the adhesive has cured and tied to its drawing revision, closes the record.

Request a Specification Review and Sample Quote

Planning a hotel, apartment or private-label vanity brand order? Dlinxcy builds OEM and ODM plywood bathroom vanities with EPA, ENF cores and PUR edge sealing. Pre-production samples take about 7 days. LED mirrors and mirror cabinets can also be provided as accessories.


Related Article:

Send Inquiry To Dlinxcy Experts

Blank Form (#3) (#4)